27th Congress of International Council of the Aeronautical Sciences, 19 - 24 September 2010, Nice, France
Paper ICAS 2010-10.6.3


DETECTABILITY COMPARISON OF THE SENSORS EMBEDDED IN GLASS-EPOXY WOVEN COMPOSITE LAMINATES

W. -G. Guo, X. -Q. Zhang, J -J. Wang
NPU, China

Keywords: woven composite, sensor, structural health monitoring, damage

The strain gauge, a thermocouple and the PVDF (polyvinylidene fluoride) piezoelectric thin film are embedded in Glass-Epoxy 2-D woven composite laminates as health monitoring technologies. The results show: Before the fatigue damage, the woven composite present the temperature rise; a thermocouple is better way to detect temperature.


view full paper